Model: Yaskawa CIMR-RT2A03P5ASA
- Series: CIMR-RT1000 Series
- Region code: Asia (Singapore and Taiwan)
- T: Asia (Singapore and Taiwan)
- A: Japan
- B: China
- C: Europe
- D: India
- K: Korea
- U: the Americas
- Input power supply voltage: 200 V 3-phase
- Rated Output Current: Check specification & datasheet
- Customized Specifications: Standard mode
- Protection Design: IP00
- Environmental specification: Vibration resistant
- Regeneration Capacity kW: 3.5
- Rated Output Current (DC) A: 14
- Rated Input Current (AC) A: 10
- Rated Voltage/Rated Frequency: 200 to 240Vac 50/60Hz
- Allowable Voltage Fluctuation: - 15 to + 10%
- Allowable Frequency Fluctuation: ± 2%
- Control Method: 120°excitation method
- Input Power Factor: 0.9 min. (for rated load)
- Overload Protection: 30 s at approx. 150% of rated current.
- Regenerative Torque: 150% 30 s, 100% 25% ED 60 s, 80% continuous
- Main Control Functions: Cooling Fan on/off Switch, Removable Terminal Block with Parameter Backup, MEMOBUS/Modbus Comm. (RS-422/RS-485 max, 115.2 kbps)
- Momentary Overcurrent Protection: Operation stops for approx. 250% or higher of the rated power supply current.
- Fuse burnout: Operation stops if the fuse burns out.
- Overloads: Operation stops for 150% of the rated power supply current for 30 s.
- Overvoltage Protection Output: Stops when DC bus voltage exceeds approx. 410 Vdc
- Overvoltage Protection Input: Stops when input voltage exceeds approx. 227 Vac
- Undervoltage Protection Output: Stops when DC bus voltage falls below approx. 190 Vdc
- Undervoltage Protection Input: Stops when input voltage falls below approx. 150 Vac
- Momentary Power Loss: Immediately stops after Momentary Power Loss is detected.
- Power Supply Frequency Fault: Operation stops for a deviation of ± 6 Hz or more from the rated input frequency.
- Heatsink Overheat Protection: Protection by thermistor
- Charge LED: Charge LED remains lit until DC bus has fallen below approx. 50 V
- Area of Use: Indoors (Protected from corrosive gases and dust)
- Ambient Temperature: − 10 to +40°C (UL Type1), − 10 to +50° C (IP00, IP20)
- Humidity: 95% RH or less (no condensation)
- Shock: (2A03P5 to 2A0053, 4A03P5 to 4A0073)10 to 20 Hz:9.8 m/s2,20 to 55 Hz:5.9 m/s2 (2A0073 to 2A0105, 4A0105 to 4A0300)10 to 20 Hz:9.8 m/s2,20 to 55 Hz:2.0 m/s2
- Storage Temperature: − 20 to +60°C(short-term temperature during transportation)
- Altitude: Up to 1000 meters (derating required at altitudes from 1000 to 3000 m) . Open Type enclosure(IP00) Enclosed Wall-Mounted (IP20/UL Type1)*2. UL508C, IEC/EN61800-5-1, IEC/EN61800-3