E2E-X10D2-U 5M Cảm biến tiệm cận Omron DC 2-Wire Shielded Normally closed (NC)

Model: E2E-X10D2-U 5M

  • Liên hệ
E2E-X10D2-U 5M là cảm biến tiệm cận Thường đóng. Thân ren M30, Shielded, sử dụng cable và điện áp DC 2-Wire. Khoảng cách phát hiện 10 mm ±10%, độ nhạy phát hiện trong khoảng 0 to 8 mm.

Datasheet E2E-X10D2-U 5M

Thông số kỹ thuật cảm biến tiệm cận Omron E2E-X10D2-U 5M

  • Form of output switching element: Normally closed (NC)
  • Size Ø: M30
  • Shielded: Shielded
  • AC/DC Wire: DC 2-Wire
  • Sensing distance: 10 mm ±10%
  • Set distance *1: 0 to 8 mm
  • Differential travel: 10% max. of sensing distance
  • Detectable object: Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.)
  • Standard sensing object: Iron, 30 × 30 × 1 mm
  • Response frequency *2: 0.4 kHz
  • Power supply voltage (operating voltage range): 12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC)
  • Leakage current: 0.8 mA max.
  • Control output Load current: 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models
  • Control output Residual voltage: 3 V max. (Load current: 100 mA, Cable length: 2 m)
  • Indicators: D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red)
  • Operation mode (with sensing object approaching): D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.
  • Protection circuits: Surge suppressor, Load short-circuit protection (for control and diagnostic output)
  • Ambient temperature: Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)
  • Ambient humidity range: Operating/storage: 35% to 95% (with no condensation)
  • Temperature influence: ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
  • Voltage influence: ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
  • Insulation resistance: 50 MΩ min. (at 500 VDC) between current-carrying parts and case
  • Dielectric strength: 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case
  • Vibration resistance: Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
  • Shock resistance: Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
  • Degree of protection: Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)
  • Connection method: Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)
  • Weight (packed state): Approx. 175 g
  • Materials Case: Nickel-plated brass
  • Materials Sensing surface: PBT
  • Materials Clamping nuts: Nickel-plated brass
  • Materials Toothed washer: Zinc-plated iron